Industry

Brief analysis on several common faults of Cummins diesel generator set

Cummins diesel generator set you are familiar with the Sino-US joint venture diesel generator set brand. Cummins diesel generator set has the advantages of simple maintenance, low maintenance cost and excellent sudden load performance. So in the use of Cummins diesel generator set several common failures are what? The following will be sorted out and published for everyone.

1. Cummins diesel generator set start-up difficulty

Check whether the battery has electricity, whether the fuel is sufficient, check whether the diesel pump is working normally, whether the diesel generator body screws loose.

2. The frequency of Cummins diesel generator set is unstable

Check whether there is voltage, speed board is damaged, diesel pipe is cracked or oil line into the air.

3, Cummins diesel generator oil pressure is normal but shut down

Check whether the oil pressure switch and controller are damaged.

4, Cummins diesel generator set during the operation of black smoke

Check whether the supercharger is damaged and whether the nozzle is working properly.

Jiangsu Meao Power Technology Co., Ltd. is an important manufacturer of diesel generators. The company mainly manufactures and sells diesel generator sets with power of 3-3000kW, mobile power station of 24-600kW, Marine emergency diesel generator set of 24-800kW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, static speaker, mobile lighthouse, container, etc.) diesel generator At the same time, we are engaged in generator set maintenance and after-sale service of generator set accessories.