Generator set maintenance, generator application technology can not start the reasons and solutions
1. The air pressure in the air bottle is too low.
Elimination measures: the pressure in the bottle should always be kept above 2Mpa.
2. No longer the best starting position.
Elimination measures: drive the flywheel 15° after the dead point on any cylinder.
3. The driving handle is not in the driving position.
Elimination measures: tighten the driving handle in the driving position.
4, diesel engine with load.
Elimination measure: remove diesel engine load.
5, generator oil fluidity is poor (in winter).
Elimination measures: according to the provisions of oil or heating oil.
6. The fuel system is not deflated.
Elimination measures: deflate according to regulations.
7. Diesel contains moisture.
Elimination measures: check the fuel tank; Unscrew the lower screw plug of the diesel filter to remove water.
8. The exhaust screw of the generator injector is loose.
Elimination measures: clockwise tightening.
9, the quality of diesel.
Elimination measures: Select diesel oil according to regulations.
10, diesel engine working environment temperature is too low.
Elimination measures: work according to regulations.
11. No oil in the diesel tank or the oil valve is not opened.
Elimination measures: refueling or release the oil valve.
Jiangsu Meiao Power Technology Co., Ltd. is an important manufacturer of diesel generators. The company mainly manufactures and sells diesel generator sets with power of 3-3000kW, mobile power station of 24-600kW, Marine emergency diesel generator set of 24-800kW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, static speaker, mobile lighthouse, container, etc.) diesel generator At the same time, we are engaged in generator set maintenance and after-sale service of generator set accessories.