The wrong operation of diesel generator will seriously affect the service life of diesel generator set. Let’s see what are the wrong operation methods of diesel generator set in daily life?
First, the diesel engine runs when the oil is insufficient.
At this time, due to insufficient oil supply, the surface of each friction pair will be insufficient, resulting in abnormal wear or burns. To this end, the diesel generator before starting and diesel engine operation process to ensure sufficient oil, to prevent the lack of oil caused by cylinder pulling, burning tile failure.
Two, with the load of emergency stop or suddenly after unloading load immediately stop.
After the diesel engine generator flout, the cooling water circulation stops, the cooling capacity is sharply reduced, the heated parts lose cooling, easy to cause overheating of the cylinder head, cylinder liner, cylinder block and other parts, crack, or make the piston excessive expansion stuck in the cylinder liner. On the other hand, diesel generator shutdown without idle cooling, will make the friction surface oil shortage, when the diesel engine will start again due to poor lubrication and aggravating wear. Therefore, the diesel generator should be unloaded before flameout, and gradually reduce the speed, no-load operation for a few minutes.
Three, after cold start without warm machine with load operation.
When the diesel generator cooler starts, due to the high viscosity and poor fluidity of the oil, the oil supply of the oil pump is insufficient, and the friction surface of the machine is badly lubricated due to lack of oil, resulting in sharp wear and tear, and even the failure of cylinder pulling and tile burning. Therefore, the diesel engine cooling start should idle operation heating up, until the oil temperature reaches more than 40℃ with load operation; The machine should start with low speed gear, and run a distance in each gear step by step, until the oil temperature is normal and the oil supply is sufficient, before turning to normal driving.
Four, the diesel engine cold start after the bang throttle.
If the throttle is slammed, the diesel generator speed increases sharply, which will cause some friction surfaces on the machine to be severely worn by dry friction. In addition, when the throttle piston, connecting rod and crankshaft acceptance force changes greatly, causing violent impact, easy to damage parts.
Five, in the case of insufficient cooling water or cooling water, oil temperature is too high operation.
Insufficient cooling water of diesel generator will reduce its cooling effect, and diesel engine will overheat because of insufficient cooling water. The high temperature of cooling water and oil will also cause the diesel engine to overheat. At this time, the diesel generator cylinder head, cylinder liner, piston components and valves and other main heat load, its mechanical properties such as strength, toughness and other sharp decline, so that the deformation of parts increase, reduce the coordination gap between parts, accelerate the wear of parts, serious will also crack, parts stuck fault. Diesel generator overheating will also worsen the diesel engine combustion process, so that the fuel injector work out of order, bad atomization, carbon accumulation.
Jiangsu Meao Power Technology Co., Ltd. focuses on the development and manufacture of diesel generator sets, and has accumulated rich experience in manufacturing and service in this field. As a professional generator manufacturer, MEAOPOWER attaches great importance to product development, innovation and service quality, and maintains close strategic cooperation with famous domestic and international enterprises such as Cummins, Perkins, Doosan, Yuchai, Weichai, Shangchai, Wuxi Wandi, Lillesomer, Stanford, Marathon and so on.