If to mute type generator set to establish a room, it must be reasonable planning and design, especially ventilation cooling to meet safety standards, mute type generator set for air intake and exhaust are very strict requirements. Reasonable planning of a good room can improve the use of quiet type generator set power, so how to quiet type generator set room cooling, the following specific to share a few cooling treatment methods.
The quiet type generator room adopts water-cooled cooling treatment, and water should be selected as the refrigerant when the water source is satisfied and the water temperature is low. When planning the equipment room, the water should be tasteless, free of bacteria and non-corrosive to metal. The content of inorganic and organic matter in the water should meet the standard, and the water temperature should be low, and the temperature and water temperature of the diesel generator room should not differ greatly, and the difference should be controlled between 10 degrees Celsius and 15 degrees Celsius.
If the water temperature is relatively high, it will require a large air supply system in the small temperature difference box, which will increase the cost and waste resources. In fact, there are other cooling methods, but the advantage of water cooling power station is that the intake and exhaust air volume are relatively small, so the need for small pipes; The water-cooled power station is basically not affected by the temperature of the external atmosphere and can ensure the cooling of the air in the machine room at any time. The disadvantage is that the water consumption is relatively large, because the water source is required to be sufficient, so the cooling effect cannot be achieved under the condition of limited water source, so this cooling method cannot be selected.
In summer, it is suitable to use air cooling to cool the machine room. The low temperature air outside the machine room is used to increase the air intake and exhaust air to clean up the waste heat of the machine room. The air-cooled power station does not need a lot of low-temperature water sources, and the ventilation system in the machine room is relatively simple and convenient to operate. But the need to use a lot of air intake and exhaust air volume, so the need for pipeline capacity is relatively large. There is another method called transpiration cooling power station, only need a small amount of water, according to the diesel engine power accounting, there are no strict requirements for water temperature, but also use half of the air intake, especially suitable for water supply difficulties and high water temperature areas.
If the water source can not be satisfied and the air inlet temperature can not be satisfied, you can use artificial refrigeration, with a cold source of the air cooler to eliminate the waste heat of the quiet type generator room. But artificial refrigeration will waste resources and manpower, thus increasing the cost, and in winter or excessive season, the general air cooling is the first choice. Diesel power station use automatic unit, after the completion of the compartment, the staff on duty generally can not enter the machine room, the high temperature of the cooling planning of the machine room can be planned by 40 degrees Celsius.
Jiangsu Meiao Power Technology Co., Ltd. is an important manufacturer of diesel generators. Us ao-generator set manufacturers mainly manufacture and sell diesel generator sets, the power of generator sets is 3-3000KW, mobile station is 24-600KW, Marine emergency diesel generator set 24-800KW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, silent speaker, mobile lighthouse, container, etc.) diesel generator Group at the same time engaged in generator set maintenance and generator set accessories after-sales service.